Installation and Setup Guide
1-2
Optional siren supervision detects external sounder wiring short or open; causes a
trouble condition, keypad display, and sends a report to the central monitoring station,
if enabled.
Optional RF jam detection for wireless systems detects a condition that may impede
proper RF reception (i.e., jamming or other RF interference); causes keypad display,
sends a report to the central monitoring station (if trouble reporting is enabled), and can
optionally send a tamper alarm if detected during the armed mode.
Individual user code selection for open/close reporting to central monitoring station (set
when adding a user code, attribute 6).
Compatible Devices
Supports up to 8 Addressable Keypads: 6148/6150 Fixed-Word Display Keypads, 6164
Alpha Keypad, 6128RF/6128RFH/6150RF/6160RF Keypad/Transceivers, 6160V Voice
Keypad
Supports a 4219 or 4229 addressable basic wired zone expander module
Supports 5881/5882EU/5882EUH/5883 series receiver and 5800/5800EU/5800H/5800AP
series transmitters
Outputs up to 4 relays, two on-board triggers, and/or Powerline Carrier Devices (X-10
type)
-- Use any combination of 4204, 4229, 6164 relays and/or Powerline Carrier Devices.
-- Output functions (up to 12)
Alarm power output provides a 12VDC, 2 AMP output that can drive compatible
sounders with a steady output for burglary/panic, or temporal pulse (3 pulses – pause –
3 pulses – pause – 3 pulses. . .) for fire. Uses current limiting circuitry for protection.
Auxiliary Power Output: 12VDC, 600 mA maximum (uses fuse for protection).
Backup Battery: Rechargeable (sealed lead-acid type) 12VDC, 6AH minimum.
Audio Alarm Verification (using AAV module, such as ADEMCO UVS); can be used in
conjunction with an output trigger to permit voice dialog between an operator at the
central station and a person at the premises.
Alternative Communication Media: Primary telephone number messages can be
reported via ECP connection to Ethernet TCP-IP Internet
AC Power Supply: Wired-in or Plug-in 110 (e.g. 1321)/220VAC transformer