EasyManua.ls Logo

Honeywell Ademco VISTA-21iPSIA - Page 70

Honeywell Ademco VISTA-21iPSIA
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STOP SMTWTFS
HH MMAM 0010000
Stop Time (For events 01-relay on/off; 02-user access; 03-latch key report)
01-12 = hour; 00-59 = minute; 0 = AM; 1 = PM; Days = place 1 under days
Press [
] to continue.
Enter the event’s stop time and days of the week to occur.
To select days, position the cursor under the desired days using the [] key to move
forward, then press “1” to select the day.
REPEAT OPTION
0-4 X
Repeat Option
0 = do not repeat; 1 = repeat weekly; 2 = repeat biweekly (every other week)
3 = repeat every third week; 4 = repeat every fourth week
Press [
] to continue.
Enter the desired repeat option for this schedule.
e.g., To make a schedule that happens everyday you would select all days with a repeat
count of 1. To make a schedule that runs for one week then stops, select everyday with a
repeat count of 0.
RANDOMIZE
0=NO 1=YES X
Randomize (For events 01 and 11)
0 = no; 1 = yes
Press [
] to continue.
If selected, the scheduled start and stop times will vary within 60 minutes of the “hour”
time. For example, if a schedule is set to start at 6:15pm, it will do so the first time 6:15pm
arrives, but on subsequent days it will start anytime between 6:00 and 6:59 p.m.
NOTE: Do not use the random option if the start and stop times are within the same “hour”
setting, otherwise unpredictable results may occur (e.g., the randomized stop time may occur
before the start time).
AVS System Enable and Quick Programming Commands
Applies to an AVS system using an ECP connection to the control.
1. Install the AVS module according to its instructions.
2. Use one of the control’s AVS Quick Program commands as follows (see Quick Program Command Results below for
results of each command):
installer code + [#] + 0 + 3: enable AVS operation without panel sounds on the AVST speaker
installer code + [#] + 0 + 4: enable AVS operation and enable panel sounds on the AVST speaker
3. Use data field 55 Dynamic Signaling Priority to enable the reporting path for AAV communication.
4. To undo the Quick Command programming, use the following commands:
installer code + [#] + 0 + 5: remove all options set by [#] + 03 quick command
installer code + [#] + 0 + 6: remove all options set by [#] + 04 quick command
Quick Program Command Results
When either the #03 or #04 Quick Program command is used, the following are automatically programmed and no longer
available for other control panel purposes.
Pre-Programmed #03 Command #04 Command
Output Function
No.
(80 mode)
46 (zone type 60, relay 15)
47 (zone type 61, relay 16)
48 (zone type 62, relay 16)
Same as #03 plus:
41 (zone type 14, relay 13)
42 (zone type 22, relay 13)
43 (zone type 39, relay 14)
44 (zone type 33, relay 14)
45 (zone type 36, relay 14
Output Relay No.
(79 mode)
15 (addr 11, relay pos 2)
16 (addr 11, relay pos 1)
Same as #03 plus:
13 (addr 11, relay pos 4)
14 (addr 11, relay pos 3)
Protection Zone
(56/58 mode)
4229 zn 48 (zt 81, addr 11) Same as #03 command
Device Address address 11 (AVS module) Same as #03 command
Data Field 91
AAV enabled AAV enabled
Installation and Setup Guide