Getting Started
Part No.: 4417584_Rev12 Configuration Manual
CIU 888 3 - 30
$*6
3.2.5.3 Modify OPC UA Properties
1. Click the OPC UA tab, the properties detail appears.
You can view or edit these properties:
Note: *Configure the Ambient Temperature settings only if ambient temperature is
measured with a GPU gauge. If ambient temperature is measured with a Modbus
gauge then configure it in Modbus Data input (refer to section 3.2.10.2).
If ambient temperature is measured with a TRL/2 gauge then configure it in TRL/2
Data input (refer to section 3.2.10.4)
Properties Description
Protocol type This setting depicts the different OPC Proto-
col type. The following type is supported.
0 – OPC UA TCP
Default value: 0
Note: OPC UA HTTPS is not supported
Server port number This setting depicts the server port number.
Range 0- 65535
Default value: 51000