Part No.: 4417584_Rev12 Configuration Manual
CIU 888 3 - 65
$*6
The CIU 888 supports density profile upward, density profile
downwards, interface profile upward, interface profile downward,
combined profile upward and combined profile downward commands
via Modbus coils.
The following steps detail out the configuration procedure.
1. On the Tank1 node, right-click and choose Add > GPU Data Input.
2. The Add Site Element window appears.
3. In the Name box, type the name of the GPU Data Input and click OK.
4. The G1 node is created and displayed under Tank1.
5. By default, the Gauge tab appears.
You can view or edit these properties:
Properties Description
Data Input Name You can see the name of the GPU Data Input
Gauge Detail Select ‘h’ for 854 gauges using the ZLQ record (up to
software version SPUA1.0) or select ‘-‘ for 854 gauges
(with software version SPUA2.0 onwards).
Gauge Type Select Unknown, 811, 854, 866, 872, 873, 877, 894,
954, 970, 971, 973, or 990.