Getting Started
Part No.: 4417584_Rev12 Configuration Manual
CIU 888 3 - 66
Allow Interface 2 com-
mand
Check the option, if allowed (I2; 854, 894, 954 only).
Allow Block gauge
Check the option, if allowed (BL; 811, 854, 894, 954 only).
Allow Tank profile Check the option, if allowed (TP; 854, 894, 954 only).
Allow Gauge alarm test Check the option, if allowed (AT; 873 only).
Allow Lock test
Check the option, if allowed (LT; 811, 854, 894, 954 only).
Allow Reset gauge Check the option, if allowed (RS).
Allow Test gauge
Check the option, if allowed (TG; 811, 854, 894, 954 only).
Allow Verify command Check the option, if allowed (CA; 854, 894, 954 only).
Allow Water dip
Check the option, if allowed (I3; 811, 854, 894, 954 only).
Allow Interface profile Check the option, if allowed (IP; 854, 894, 954 only).
FlexConn address Set the option, if allowed (954, 990 Only).
Primary Gauge This indicates whether the gauge is primary or not. For
primary gauge, all measurements can be enabled for
scan and gauge commands can be enabled. For sec-
ond gauge (non-primary), only product level measure-
ment can be enabled for scan and gauge commands
are not supported.
Wire Compensation This setting enables (or) disables servo wire correction.
This is applicable only for Servo gauge. When enabled,
product level is corrected for the temperature effects on
the Servo wire.
Note:
- Servo wire correction is supported by 954 Servo
gauge, if enabled in gauge do not enable this correction
in CIU.
Servo Wire thermal exp.
coeff.
Thermal expansion coefficient of the servo wire. Unit of
measure is 10E-5/C (or) 10E-5/F.
Note:
Thermal expansion coefficient values in ppm (10E-6/C
(or) 10E-6/F) needs to be converted to 10E-5/C (or)
10E-5/F. For example, the value of 16 10E-6/C (ppm)
needs to be converted to 1.6 and then set in Service
tool.