Chapter 4 — Printer Options
22 PrintPAD Series CN70/70e & CN51 User Guide
DEX/UCS Port
DEX/UCS Port: Use this illustration to locate the DEX/UCS port on the printer.
The direct exchange (DEX)/UCS port can only be used with the Datamax-
O’Neil by Honeywell-approved DEX cable (P/N: 210237-xxx).
When the DEX cable is plugged into the data port, the printer automatically
turns off to allow data transfer between the mobile computer and the DEX port.
Remove the DEX cable to resume normal connection to the printer.
DEX/UCS port
Note: Do not unplug the cable in the middle of the data transfer session. Your
application needs to be programmed to communicate in the DEX/UCS
language.