EasyManua.ls Logo

Honeywell EGPWS MK VII - SECTION 4 RAAS Options

Honeywell EGPWS MK VII
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mark V and Mark VII EGPWS Pilot’s Guide
Smart Runway
®
060-4241-000
92 Rev H, August 2011
SECTION 4
RAAS
Options
The options listed below are set in the RCD and setup during
the installation of RAAS. The flight crew cannot configure
them.
RAAS Options
:
Configurable Feature Option
Distance Unit of Measurement Feet or Metres
Voice Gender Female or Male
GPS Antenna Location
Customer-selected location based on aircraft
installation
Taxiway Takeoff Off or On
Caution Taxiway Takeoff Off or On
Insufficient Runway Length - On Ground
(Takeoff)
Off or On using customer - selected nominal
runway length based on aircraft type, or always
On
Caution Short Runway On Ground (Takeoff) Off or On
Extended Holding - On Runway
INITIAL: 60, 90, 120, 180, 240, 300, Off
REPEAT: 30, 60, 90, 120, 180, 240, 300, Off
Distance Remaining - Rejected Takeoff
Off or On (50% of runway) or with -224 or later
software selected distances 1000 (300), 2000
(600), 3000 (900), 4000 (1200) or 5000 (1500)
Feet (meters)
Approaching Runway - In Air
Advisory suppression zone
Off or On
550 - 450 feet AFE or 450 - 350 feet AFE
Approaching Short Runway - In Air (Landing)
Off or On using customer - selected nominal
runway length based on aircraft type, or always
On
Caution Short Runway In Air (Landing) Off or On
Distance Remaining - Landing
Off or On (50% of runway) or with -224 or later
software selected distances 1000 (300), 2000
(600), 3000 (900), 4000 (1200) or 5000 (1500)
Feet (meters)
Runway End Callout Off or On
Taxiway Landing Off or On
Take-off Flap Off or On
Male or Female voice
Inhibit control
Minimum and Maximum Flap setting