EasyManua.ls Logo

Honeywell FocusPRO TH6000 Series - Power Options; Wiring Terminal Designations

Honeywell FocusPRO TH6000 Series
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FocusPRO
TM
TH6110 / TH6220 / TH6320
3
Power options
Keep wires in this
shaded area
Connect C for primary AC power
(optional if batteries are installed).
Insert batteries for primary
or backup power.
Remove factory-
installed jumper
only for two-
transformer
systems.
Conventional Terminals:
Rc 24VAC power from cooling
transformer
R 24VAC power from heating
transformer
W Heat relay (stage 1)
W2 Heat relay (stage 2)
Y Compressor contactor (stage 1)
Y2 Compressor contactor (stage 2)
G Fan relay
C 24VAC common. For 2 transformer
systems, use common wire from cooling
transformer.
Heat Pump Terminals:
Rc 24VAC power from cooling
transformer
R 24VAC power from heating
transformer
O/B Changeover valve
Y Compressor contactor (stage 1)
Y2 Compressor contactor (stage 2) -
TH6320U only
G Fan relay
Aux Auxiliary heat relay*
E Emergency heat relay*
L Sends output when set to Em. Heat
C 24VAC common
Wiring
Terminal designations
Shaded areas below apply only to TH6320U/TH6220D or as otherwise noted.
TH6110D
RcYWG RC
TH6110D
RcYG RC
TH6220D
Rc
YWGW2Y2
R
C
RcYGAuxEL RC
TH6220D
TH6320U
Rc
YWGW2Y2
R
C
RcYGAux
E
Y2L RC
TH63 20U
TH6110D
RcYWG RC
TH6110D
RcYG RC
TH6220D
Rc
YWGW2Y2
R
C
RcYGAuxEL RC
TH6220D
TH6320U
Rc
YWGW2Y2
R
C
RcYGAux
E
Y2L RC
TH63 20U
*Aux and E terminals combined on TH6320U only.