EasyManua.ls Logo

Honeywell Galaxy 2 Series - Section 5: Hardware; PCB Layout (2-44+)

Honeywell Galaxy 2 Series
118 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11
Galaxy 2 Series Installation Manual
SECTION 5: HARDWARE
PCB Layout (2–44+)
Figure 4. Galaxy 2–44+ PCB Layout
PCB Layout
SW 1
AC power
TAMPER
Zone Terminals
COM
N/O
TRIG
N/C
BELL
+12v
0v
T
SAB
Connections
Loudspeaker
DI
DO
AUX+
AUX-
A
B
AUX+
AUX+
LED2
BELL FUSE
AUX FUSE
F3
F2
F1
BATTERY FUSE
Program
Header
Processor
Alternative
Phone
Socket
B
A
B
LINE IN
A
Extension
Phone Output
Phone Line
Input
Data in
Data out
12V Aux
Output
RS 485 peripherals
BATT
+
BATT
-
Trigger
Header
Audio
Connector
LK1
RELAY
Engineer
Header
Battery
Terminals
For ECP
peripherals
see Note
Note: If Relay is fitted the TRIG terminal
is used as N/C for Relay.
If Relay is not fitted the COM & N/O terminals
are not fitted. The TRIG N/C terminal is
the transistorised output.
HEATSINK
Tamper Spring
Note: Switch SW1 and the
tamper spring are for the
plastic box only.
The metal box has a 2-way
terminal for connection to
the lid tamper microswitch.
RIO 0
RIO 1
1
2
0v
3
4
0v
5
6
0v
7
8
9
10
0v
0v
11
12
0v
LED 1
Telecoms
2-way header
RS485 termination

Table of Contents