EasyManua.ls Logo

Honeywell Granit XP 1991iXR - Base;Access Point Communication and Scanning; Base Power Communication Indicator

Honeywell Granit XP 1991iXR
312 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Granit XP User Guide 47
Base/Access Point Communication and Scanning
The following feedback is provided by the base (red LED) or Access Point (blue
LED) and indicates communication and scanning status.
Base Power Communication Indicator
To display the power indicator on a base or an Access Point, scan the Base Power
Communication Indicator On barcode. To turn off the power indicator, scan the
Off barcode. Default = On.
When the
scanner is out
of the base and
has been idle
for 5 seconds
3 sets of
flashes
repeatedly
every 3
seconds
No beep <15%
3 sets of
flashes
repeatedly
every 3
seconds
No beep <5%
20 sets of
rapid flashes
No beep <2%
Battery Icon
LED
Red Yellow Green
Scanner
Beep
Charge
Level
LED Communication Condition
Off USB suspend
On continuously Power on, system idle
Short blinks in multiple pulses. Occurs while
transferring data to/from the RF module or
the Host port.
Receiving data
* Base Power Communication
Indicator On
Base Power Communication
Indicator Off

Table of Contents