EasyManua.ls Logo

Honeywell GSMV4G - Page 35

Honeywell GSMV4G
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 3: Programming the Communicator
3-17
PROMPTS
ZONE
TRIG.
4204/
2-4204
OPTIONS DESCRIPTION
57
Rpt Zn6 ONLY if
Armed (N)_
X X
[Y], [N]
Reports alarms on zone 6 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 6.
58
Enable Zn7 Y/N
(N)_
4204
only
[Y], [N]
Enables alarm reporting for zone 7, if used.
If [N], skip to Prompt 66: "Review."
59
Zn7 Trigger Type
(V+)_
X
4204
only
(EOLR)
(V+)
(V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
60
Invert Zn7 Y/N
(N)_
X
4204
only
[Y], [N]
Inverts the alarm and normal states of the zone 7
trigger; otherwise uses normal input signal.
61
Restore Zn7 Y/N
(Y)_
X X
[Y], [N]
Enables restore reporting for zone 7.
Zone Trigger mode: This question will only be
displayed if zone 7 is not used as the conditional
(arming) trigger zone.
UL/ULC: Must be set to “Y.”
62
Delay Zn7 (secs)
(00)_
X X
[01-15]
[00] = no delay
Defines the reporting delay in seconds for
zone 7.
Zone Trigger mode: This question will only be
displayed if zone 7 is not used as the conditional
(arming) trigger zone.
UL/ULC: Must be set to “00.”
63
Rpt Zn7 ONLY if
Armed (N)_
X
[Y], [N]
Reports alarms on zone 7 ONLY if the conditional
zone (zone 4 in 4204 mode; zone 8 in 2-4204 mode) is
triggered (armed).
If [N], always reports alarms on zone 7.
2-4204 mode: If any zone is programmed to "Report
Only if Armed," or if tamper is enabled, skip to
"Review."
NOTE:
The next two prompts (2 x 4204 Emulation Device Mode) are available ONLY when option "Tamper Rpt" is
DISABLED.
64
Restore Zn8 Y/N
(Y)_
2-
4204
only
[Y], [N]
Enables restore reporting for zone 8.
UL/ULC: Must be set to “Y.”
65
Delay Zn8 (secs)
(00)_
2-
4204
only
[01-15]
[00] = no delay
Defines the reporting delay in seconds for
zone 8.
UL/ULC: Must be set to “00.”
66
Review? Y/N
X X
[Y] = review
[N] = exit
Reviewing Programming Mode Entries
To review the programming options (to ensure that
the correct entries have been made), press [Y]. The
programming questions are displayed again. Use
the up/down arrow keys to scroll through the
program fields without changing any of the values.
If a value requires change, simply type in the
correct value. When the last field is displayed, the
“REVIEW?” question again appears.
To exit the programming mode, press [N] in
response to the "REVIEW?" question, and refer to
Exiting Programming Mode below.