21
Figure 3-2 Sample of Alarm Input (Normal Close Type)
Alarm Output Port
Three ways to relay alarm output (NO contact). External power supply
is needed for external alarm device.
To avoid overloading, please read the following relay parameters sheet
carefully.
6 ways relay alarm output (NO contact). Provide external power to
external alarm device.
For controllable +12V, it can be used to provide power to devices such
as reset smoke sensor.
Table 3-1 Relay Specification:
Model JRC-27F
Material of the touch Silver
Rated switch capacity 30VDC 2A, 125VAC 1A
Maximum switch power 125VA 160W
Maximum switch voltage 250VAC, 220VDC
Rating (Resistance
Load)
Maximum switch currency 1A
Between touches with same
polarity
1000VAC 1minute
Between touches with
different polarity
1000VAC 1minute
Insulation
Between touch and winding 1000VAC 1minute