49
PTZ Setup
Note
The camera video should be in the current screen.
Before setup, check whether the following connections
are right:
PTZ and decoder connection
Decoder address setup
Decoder A (RS485 +) / B (RS485 -) line connects with
DVR A/B line
Boot up the DVR, and input the user name and password.
In the main menu, select SettingPan/Tilt/Zoom. The interface is shown
as in Figure 4-27. Here you can set the following items:
Channel: Select the channel connected with the speed dome video
port.
Protocol: Select the corresponding PTZ protocol (such as PELCOD).
Address: Identical to the device address set in the speed dome.
Default address is 1.
Baud rate: Select corresponding baud rate. 2400 for Pelco-D
protocol.
Data bits: Select corresponding data bits. Default value is 8.
Stop bits: Select corresponding stop bits. Default value is 1.
Parity: There are three options: Odd/Even/None. The default value
is None.

Table of Contents