Specifications and Model Selection Guide
2/03 10260A Series Actuators – Installation, Operations, and Maintenance 11
2.3 Model Selection Guide
Instructions
Select the desired key number. The arrow to the right marks the selection available.
Make the desired selections from Tables I thru VII using the column below the arrow.
A dot ( ) denotes unrestricted availability.
Key Number I II III IV
VVI VII
_ _ _ _ _ -
-
-
_-
-
_ _ _ _ -
_ _ -
KEY NUMBER - Electronics
Selection Availability
Output Torque Full Travel Stroking - Time in Seconds
(lb. - ft.) (N - M) 60 Hz 50 Hz
10 (15) 10 12 10261A
20 (27) 20 24 10262A
40 (55) 40 48 10264A
60 (80) 60 72 10266A
40 (55) 20 24 10267A
80 (110) 40 48 10268A
150 (200) 60 72 10269A
200 (270) 40 48 10263A
300 (400) 60 72 10265A
TABLE I - POWER SUPPLY - SINGLE PHASE
120 VAC 60 Hz Single Phase 120 VAC 60Hz Motor 1
120 VAC 50 Hz Single Phase 120 VAC 50Hz Motor 2
220/240 VAC 60 Hz Single Phase 220/240 VAC 60Hz Motor 3
220/240 VAC 50 Hz Single Phase 220/240 VAC 50Hz Motor 4
TABLE II - CONTROLS
Up/Dn Drive Up/Dn 0
4-20mAdc / 1-5Vdc 4-20mAdc or 1-5Vdc (w/resistor change) 1
TABLE III - CUSTOMER POSITION OUTPUTS
None No position outputs provided 00
SEC
(Note 1)
One slidewire emulation output (3-Wire Pos. Proportional)
01
Analog Output
(Note 2)
4-20mAdc, 0-20mAdc, 0-5Vdc, 1-5Vdc, or 0-1.25Vdc 03
Film Potentiometer Dual 1000 ohm 04
d
(Note 3)
Single 1000 ohm 05 e
TABLE IV - CONTACT OUTPUTS
Limit Switches 1 CW & 1 CCW Limit Switch 0
Limit/Auxiliary Switches 1CW, 1CCW, & 2 Auxiliary SPDT Switches 2
Limit/Auxiliary Switches 1CW, 1CCW, & 4 Auxiliary SPDT Switches 4
Limit/Auto-Manual 1CW, 1CCW, Auto/Man Switch 5
Limit/Auto/Auxiliary 1CW, 1CCW, Auto/Man Switch & 2 Aux 7
Limit/Auto/Auxiliary 1CW, 1CCW, Auto/Man Switch & 4 Aux 9
Note 1:
Slidewire emulation output is a solid state emulation circuit providing a ratiometric voltage
slidewire signal without utilizing an actual slidewire. Emulates slidewires using voltages up to 20.0Vdc.
Note 2:
Analog output is factory set to 4-20mAdc. Additional listed outputs are customer selectable by
jumper and/or output resistor selection.
Note 3:
135 ohm available with 158 ohm resistor supplied with actuator.
100 ohm available with 110 ohm resistor supplied with actuator.