Description
UsermanualforHONR100gaspressureregulatorwithHONP095NGpilot 20
AnoverviewoftheconnectionlinesfortheHON R100NGactuatorassemblyandthe
HON P095NGpilotcanbefoundinLayoutandoperation(seepage12).
Theactuatorassemblysportshavethefollowingsizes:
Devicemodel Connection Size Pipediameter
HON R100NG
HON R100NG‐FO
Motorizationpressure G1/4"
10 mm,12 mm,
1/2"
HON R100NG
HON R100NG‐FO
Outletpressurefeedback G1/2"
10 mm,12 mm,
16 mm,1/2"
HON R100NG
HON R100NG‐FO
Outletpressure G1/4"
10 mm,12 mm,
1/2"
Thepilotsfittingshavethefollowingsizes:
Devicemodel Connection Size Pipediameter
HON P095NG‐MP
HON P095NG‐HP
Pressuregauge(loading
pressure)
G1/4" 10
HON P095NG‐MP
HON P095NG‐HP
Inletpressure
G1/4" 10
HON P095NG‐MP
HON P095NG‐HP
Outletpressure(measuring
line)
G1/4" 10
HON P095NG‐MP
HON P095NG‐HP
Outletpressure(feedback)
G1/4" 10
HON P095NG‐MP
HON P095NG‐HP
Motorizationpressure(actua‐
torassembly)
G1/4" 10
Thepropertiesofthegasconveyedthroughthedevicesmustmeettherequirementsspeci‐
fiedbytheDVGWGermanTechnicalandScientificAssociationforGasandWaterinthelatest
versionofDVGWCodeofPracticeG 260(A).
Thedevice’smechanicalcomponentsdonotcontainanypotentialsourcesofignition,and
accordinglydonotfallunderthescopeofATEX 95 (94/9/EC).Theelectricalcomponentsused
onthedevicemeetallapplicableATEXrequirements.
Connectionlines
Gasproperties
ATEXspecifications

Table of Contents