38 | Performance Series HQA Digital Video Recorder User Guide
Configuring PTZ Connection Settings
Before you can control a PTZ camera with the DVR, you must configure the PTZ connection
settings.
To configure the PTZ connection settings
1. Go to Main Menu > Setting > System.
2. In the left navigation pane, click Pan/Tilt/Zoom.
3. Configure the following settings:
4. Click Apply, and then click Save to save your settings and exit.
•Channel
Select the channel (camera) that you want to configure PTZ settings for.
Control Mode
Select
Serial
.
•Protocol
Select the camera’s PTZ control protocol from the list.
Address
Enter the camera’s address (ID).
•Baudrate
Select a value between
1200
and
115200
. The default setting is
9600
.
Data Bits
Select a value between
5
and
8
. The default setting is
8
.
•Stop Bits
Select
1
,
1.5
, or
2
. The default setting is
1
.
•Check
Select
None
,
Odd
,
Even
,
Mark
, or
Space
.

Table of Contents