Performance Series HQA Digital Video Recorder Local User Guide
62
NR Select a value between 0 and 100. The default setting is 50.
6. Click Apply to save your settings.
Configuring Encoding Settings
To configure a camera’s video and audio encoding settings
1. Go to Main Menu Setting Camera Encode.
Figure 8-3
2. On the Encode tab, in the Channel box, select the camera that you want to configure.
3. Configure the following settings for the primary stream and secondary stream:
Type Set the primary stream type as Regular, MD (Motion
Detection), or Alarm. The secondary stream type is not
configurable.
Compression This setting is not configurable.
Smart Codec Select Start from the drop-down menu to enable the Smart
Codec function, which reduces the video bit stream for
non-important recorded video to maximize storage space.
Resolution Set the primary stream to one of the following resolutions:
2560 x 1440, 1080P, 720P, 960H, D1, HD1, 2CIF, or CIF.
Set the secondary stream to one of the following
resolutions: D1, CIF, or QCIF.
Frame Rate Select a value between 1 and 30 (NTSC) or 1 and 25 (PAL)
for the Main Stream. Select a value between 1 and 15
(NTSC) or 1 and ? (PAL) for the Main Stream.
Bit Rate Type Set to CBR (constant bit rate) or VBR (variable bit rate).