Configuring Event Settings
97
2. Select a preset, tour, or pattern from the drop-down menu.
Click Save.
Delay
The system can delay recording for a specified amount of time after an alarm
has ended. Select from 10s to 300s.
Tour
Click to enable a tour to be triggered by an alarm. The system supports 1/8-
window tour. See Configuring Display Settings on page 119 for tour interval
setup. On the Display Settings tab, when there are two tours enabled by
default, you can configure the system so an alarm triggers the system to
enable the alarm tours you configured here. If there is no alarm, then the
system uses the tour setup that was configured in the Display interface.
Snapshot
Click to enable the Snapshot function. Channel snapshots are taken according
to the schedule you configure. Alarm snapshots are taken when an alarm
occurs.
Video Matrix
Click to enable. When an alarm occurs, the SPOT OUT port video (a 1-
window tour) from the alarm activation channel selected in the Record
Channel.
Buzzer
Click to enable the Buzzer function. When an alarm occurs, the buzzer
beeps.
Log Click to enable the DVR to record a local alarm log.
Voice Prompts
Select to enable audio broadcast/voice prompts in response to a motion
detection event.
File Name Select a file for the voice prompt.
Configuring Abnormality Settings
There are three types of system events that can be configured in the Abnormality tab:
HDD errors (no disk, disk error, no space)
Network errors (no connection, IP conflict, MAC conflict)
User errors (illegal logins)