Performance Series HQA Digital Video Recorder Local User Guide
82
Password: Enter the authorization passwords for both the ReadOnly and Read/Write
users.
Encryption Type: Select the encryption type for both the ReadOnly and Read/Write users.
The default setting is CBC-DES and is currently the only encryption option.
Password: Enter the encryption passwords for both the ReadOnly and Read/Write users.
5. Click Apply to save your settings.
6. If you want to exit the Setting menu, click Save.
Configuring Multicast Settings
Multicast allows for simultaneous real-time monitoring of live video from the DVR at multiple
remote locations over the network.
To configure multicast settings
1. Go to Main Menu Setting Network Multicast.
Figure 9-11
2. On the Multicast page, select the Enable check box to enable multicast.
3. In the IP Address box, enter a multicast IP address. The address must be valid for
multicasting and should be in the range 224.0.0.0 to 239.255.255.255 for IPv4 or have
the prefix ff00::/8. An address in the range 239.252.0.0 to 239.255.255.255 is
recommended.
4. In the Port box, enter a multicast port number or use the default setting (36666).
5. Click Apply to save your settings.
6. If you want to exit the Setting menu, click OK.