EasyManua.ls Logo

Honeywell HRHT4166 - Page 55

Honeywell HRHT4166
112 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration | 55
800-22740 - A - 02-2017
Figure 3-21 FTP Configuration Interface
Click FTP Test to test the FTP connection. A popup window shows the status of the connection.
Table 3-11 FTP Configurations
Setting Description
Server IP Enter the IP address for the server.
Port Enter the Port number for the server.
User Name Enter the user name for logging into the server.
Password Enter the password for logging into the server.
Anonymous Click to enable/disable anonymously logging into the server.
Remote Directory When the remote directory is null, the DVR automatically creates folders
according to the IP, time, and channel.
File Length Here you determine the size of the upload file. If the setup file size is
larger than the actual file, then the system uploads the entire file. If the
setup file size is smaller than the actual file, then the system uploads only
the set file size. If you enter 0 here, then the system uploads all
corresponding files.
Image Upload
Interval
This is the interval that the CVR waits through before uploading an image
to the FTP site. Select from 0 to 3600 seconds. 0 means that there is no
interval.
Channel Select a channel.
Weekday Select a weekday.
Time Periods You can configure up to two time periods per channel.

Table of Contents