INTELLIGUARD 9000
74-3047118
NOTE: Onl
y
one
g
round connection is re
q
uired between the
I9000 CU and each RIPS for
g
round reference
(
this
can be throu
g
h the earth
g
round connection
)
. Avoid
g
round loops.
5.
When installation is complete and power is applied,
learn the ISPs in the RIPS.
NOTE: Steps 5 a. throu
g
h 5
g
. ma
y
be replaced b
y
usin
g
the
PRO 9000 software. See the Commission section,
steps 1a. throu
g
h 1c. for more information.
a. Make sure the LED DS1 on each installed ISP
(
RIPS
)
in enabled, see the followin
g
notes.
b. From the CC2, select
CONFIGURATION
from the
MODE menu.
c. From the CC2, select
LEARNING
MODE.
d. From the CC2, select
1-DEVICES WITH ADDRESS
SWITCHES
. The CC2 displa
y
s
Searching
. The
LED DS1 on each installed ISP flashes as it is
learned.
e. The CU polls all address t
y
pe devices and when
the
y
have all been learned, the CU automaticall
y
displa
y
s
DEVICES = #
, where
#
is the total number
of devices known b
y
the s
y
stem includin
g
ISPs.
f. The LED DS1 on each installed ISP flashes each
time the device is polled b
y
the CU.
g
. From the CC2, exit from the CONFIGURATION
menu for chan
g
es to become effective.
NOTES:
The RIPS have two auxiliar
y
power outputs. Each
output supplies 12.8 Vdc nominal with a current
limited to 400 mA.
The ISP data LED is active when TB3 pins 3 and
4 are shorted
(
tamper is active, cover open
)
.
Fig. 18. ISP wiring, configuration.
1234 1234 1234 1234 1234
TB1 TB2 TB3 TB4 TB5
4
1
R21
DS
XA1
S1
S1
ON
1
2
3
4
ADDRESS
SELECTION
NOT USED
OUTPUT MODE
SWITCHES SHOWN IN
OFF POSITION
1
2
S1
ON
OFF
1
2
S1
ON
OFF
1
2
S1
ON
OFF
1
2
S1
ON
OFF
0123
ISP ADDRESS
4
S1
ON
OFF
4
S1
ON
OFF
PULSATING STEADY
OUTPUT MODE
AC ON
GROUND
BATT. 1 & 2 -
BATTERY 1 +
BATTERY 2 +
AC
AC
COMMON -
22V +
OUTPUT -
OUTPUT +
TAMPER -
TAMPER +
VX1 -
VX1 +
TxRx -
TxRx +
VX2 -
VX2 +
12V
7 Ah
16V
37 VA
GIM
1A
12V
0.4A
12V
0.4A
RS-485
COM 1 OR COM 2
J1
DS1 = Tx DATA
M16079B
LEVER
1
EXCEEDING 400 mA ON EITHER VX1 OR VX2 WILL CAUSE THE OUTPUT TO SHUT
DOWN UNTIL THE CAUSE OF OVERLOAD IS REMOVED.
1
2
1