Lyric Controller Programming Guide
Program Communicator
A router is required if you are utilizing WiFi for communications. The router must be powered on
and connected for WiFi operation (alarm reporting) to occur. The panel must be connected to the
WiFi network in order to communicate with AlarmNet 360. The router name and password will be
required.
Remote Access (Total Connect) and Multi Mode (PSD) over WiFi or Cellular cannot be enabled in the
panel alone. Availability of this service is controlled via the web-based programming tool on the
AlarmNet 360 website. These features must be enabled through the AlarmNet 360 website first and
transferred to the device.
Where applicable, use the down “
˅
arrow to scroll to the subsequent pages of options. Use the “
˄
arrow to
return to the previous page. The Lyric Controller Communications must be programmed using AlarmNet 360.
The APL, City ID, CS ID, Supervision, Old Alarm Time, Remote Acc. Comm., Multi Mode Comm., WiFi Fault Time,
Cellular Fault Time, Cellular Rollover, Cellular 24 Hour Test fields can be viewed but are not programmable
locally on the Lyric Controller. The options for those fields are shown for reference only. Only the
Communications Path, DHCP and IP Address fields can be programmed locally on the Lyric Controller.
Programming Field
Function and Action
Programmed
Default
Communications
Path
Select the type of Communications Module.
NOTE:
The available options are
dependent upon which
communications module(s) has been installed. If
Communication Path is set to Cellular, the control will
report to AlarmNet 360 over the Cellular network not
WiFi.
Options:
None
WiFi
Cellular
WiFi & Cellular
WiFi
APL
Enables or disables Advanced Protection Logic.
Options:
Disabled
Enabled
Disabled
City ID
2-digit Central Station Primary City ID (Decimal).
Options:
01-99
Blank
CS ID
2-digit Primary Central Station ID (Hex).
Options:
01-FE
Blank
Sub ID
4-digit Subscriber Account Number (Decimal).
Options:
0001-9999
Blank
Supervision
Determines how often the Communications Module sends
supervisory messages to the Central Station.
Options:
None
24 Hours
30 Days
30 Days
Old Alarm Time
Determines how long the system will attempt to redeliver an
undeliverable alarm message to the Central Station.
Options:
10 Minutes
15 Minutes
30 Minutes
1 Hour
2 Hours
4 Hours
8 Hours
12 Hours
24 Hours
10 Minutes
- 10 -