Lyric Controller Programming Guide
Program Communicator (Continued)
Programming Field
Function and Action
Programmed
Default
Remote Acc. Comm.
Enables or disables user remote access via internet and/or Cellular.
Options:
Disabled
Enabled
Disabled
Multi Mode Comm.
Enables or disables Multi Mode feature.
NOTE:
This field will only be viewable if Remote Acc. Comm. Is
enabled.
Options:
Disabled
Enhanced Reports
Disabled
WiFi Fault Time
(min)
Determines time delay before the Communications Module notifies
the control panel of a loss of contact with the internet. Appears only
if WiFi is enabled in Communications Path field. Enter the 2-digit
time delay (in minutes).
Options:
00-99
00
Use DHCP
Allows the panel to dynamically select the IP addresses.
NOTE:
If “No” is selected, four additional programming fields are
displayed.
Options:
Yes
No
Yes
NIC IP Address
This field only appears if “No’ is selected in the Use DHCP field. Enter
the 4-part Network Interface Card (NIC) IP address (up to 12 digits).
255.255.255.255
Subnet Mask
This field only appears if “No’ is selected in the Use DHCP field. Enter
the 4-part Subnet Address (up to 12 digits).
255.255.255.255
Gateway IP Address
This field only appears if “No’ is selected in the Use DHCP field. Enter
the 4-part Gateway IP Address (up to 12 digits).
255.255.255.255
DNS Server IP
Address
This field only appears if “No’ is selected in the Use DHCP field. Enter
the 4-part Domain Name Server IP Address (up to 12 digits).
Select “Save” and then select “OK” when the “Programming Done”
screen appears.
255.255.255.255
Cellular Fault Time
(min)
Determines time delay before the Communications Module notifies
the control panel of a loss of contact with the network. Appears only
if Cellular is enabled in Communications Path field. Enter the 2-digit
time delay (in minutes).
Options:
00-99
60
Cellular Rollover
Allows Supervision messages to be sent over Cellular in the event
that contact with the internet is lost. Appears only if “WiFi &
Cellular” is enabled in the Communications Path field.
Options:
No
Yes
No
Cellular 24 Hour Test
Enables daily test of Cellular module operation. Appears only if
“WiFi & Cellular” is enabled in the Communications Path field.
Options:
No
Yes
Select “Save” and then select “OK” when the “Programming Done”
screen appears.
No