Lyric Controller Programming Guide
Program Keys
The Lyric Controller features 32 Wireless Key (RF Key Fob) Zones that allow it to support a combination of one,
two, four, six and eight button devices. It should be noted that once a SiX™ Series wireless key (key fob) has
been enrolled in the panel it must be deleted before it can be enrolled in a different panel. Refer to deleting
Wireless Zones or Keys section for additional information.
Programming Field
Function and Action
Keys
Select the “Add new” button to enroll a new wireless key.
Key Type
Select the specific type of key being entered or enrolled. The system scrolls through
the available options.
NOTE:
Before enrolling a SiXFOB wireless key select “Key Fob”, if you are enrolling four buttons
or “Key Fob 8 Button” if you are enrolling all 8 buttons.
SIA Installation:
Select “Key Fob 8 Button and refer to the SiXFOB Installation Instructions.
Options:
Key Fob 1 Button
Key Fob (4 Button)
Key Fob 8 Button
Key Fob 2 Button
Key Fob 6 Button
User
Select a User from the displayed list.
Options:
Master
Guest
Duress
User 3 User 46
NOTE:
The wireless key must be associated with a specific User/User Code in order for it to
operate. Refer to the Lyric User Guide for additional Information regarding User Codes.
Serial Number
When Serial Number
has been selected “Enter Serial Number or Activate” is displayed.
Follow the applicable steps below to enroll the SiX™ or 5800 Series Wireless Keys.
Enroll SiXFOB wireless keys
(Refer to the documentation provided with the SiXFOB
wireless key for additional information.)
1. Press and release the top two buttons on the SiXFOB. The wireless key’s left and
right LEDs will alternately flash green. Allow up to 20 seconds for pairing to
complete. If the sensor has been successfully paired with the control the wireless
key’s green LED will light steady for three seconds, the device serial number is
displayed on the screen and the panel beeps two times. If the pairing is not
successful, press the top two buttons again to restart the enrollment and repeat
this step.
2. Press and release the top two buttons on the wireless key to confirm. The system
beeps three times and returns to the Zone Programming Screen.
3. Assign a User and select “Save”
4. The system returns to the Wireless key programming screen and the fob’s zone
information is displayed.
5. The wireless key’s battery level and signal strength can be viewed on the Zone
programming screen.
Enroll 5800 Series Wireless Keys
The transmitter serial number and loop number can be enrolled via RF transmission
OR manually.
Enroll via RF Learning
-
To enroll the 5800 device using RF Learning mode, press and
release any button on the wireless key. Three transmissions of the device will be
required. The initial transmission activates the RF Learning mode and the system will
emit a single beep. A second transmission enrolls the serial number and the system
beeps two times and displays “Activate Sensor Again To Confirm”. A third
transmission will confirm the serial number. The system beeps two times and returns
to the programming Screen.
Enroll 5800 Devices Manually - Enter the 7-digit serial number printed on the
transmitter using the displayed keypad and select “Done”. The system beeps one time
and returns to the programming Screen.
Zone
The system displays the next available Key Zone Number. Select “Zone” to manually
enter a specific 3-digit Zone Number on the displayed keypad.
NOTE:
If the desired Zone Number is not available, the system returns to the previous screen.
Options:
131-162
Select ”Done”. The system returns to the previous screen. Repeat the previous step to
enter another Zone Number.
- 16 -