Lyric Controller Programming Guide
Communications Diagnostics (Continued)
WiFi Protected Set up (WPS)
NOTE:
For WPS operation, press the WPS button on the access point first. Then press the WPS button
within 2 minutes
1. Select “WPS”, the system displays “Please Stand-by for WPS Operation…”.
2. If the operation is successful the system displays “Device has been successfully added to the network.”
Select “OK” to confirm the selection.
3. If the operation is unsuccessful the system displays “Failed Operation. Device not added to the
network.” Select “OK”.
WiFi Information
The following information is displayed:
Message
Function
WiFi Link:
Confirms physical link connection and speed (*** Mbps or Bad)
DHCP:
Displays status of server (OK, Bad or Off)
NIC IP Address:
Displays the communication device’s assigned IP address
Subnet Mask:
Displays the 32-bit address mask used to indicate the portion
(bits) of the IP address that is being used for the subnet address
Gateway IP Address:
Displays the IP address assigned to the Gateway
DNS Server IP Address:
Displays the IP address assigned to the DNS server
Cellular Information
The following information is displayed:
LYRIC-3G Communications Module
Message
Function
Cell Phone Type:
UMTS
Model:
Displays model number (i.e.; PHS8-USA)
IMEI:
Displays device’s 15-digit serial number
ICC ID:
Display SIM Card’s 20-digit serial number
Registration Status:
Displays registration status
(Home, Registration Failed - not registered, Registration Denied,
Registration Unknown, Roam, Searching)
Access Technology:
UMTS/HSDPA/HSPA (3G) OR GSM (2G)
Channel:
Displays 4-digit RF channel no.
Ec/No
Power to Noise Ratio (in -dBm)
RSCP
Displays signal code power (in -dBm)
LYRIC-CDMA Communications Module
Message
Function
Cell Phone Type:
CDMA
Model:
Displays model number (i.e.; SL3010T)
ESN/MEID:
Displays Device’s 32-bit serial number
Registration Status:
Displays registration status
Access Technology:
CDMA 1X
Channel:
Displays 3-digit RF channel no.
Ec/lo
Ratio of Signal Power to Overall Noise (in -dB)
RSSI
Displays RSSI signal strength (in -dBm)
If the Cellular is not registered the following may be displayed:
Configuring radio module Please wait…
Radio module powered up but not initialized yet Please wait…
Radio module operation suspended cannot retrieve information
Radio module failure SIM error
Radio module failure Cannot initialize radio module
Radio module in airplane mode reconfiguring and rebooting please wait…
Radio module powering up please wait…
- 26 -