Lyric Controller Programming Guide
Communications Diagnostics (Continued)
Communication Status
- The following information is displayed:
Message
Function
Cellular and/or IP:
Displays Network Connectivity status (OK, Fault Reported!, Not Connected,
Not Registered! Or No Physical Link)
Encryption:
Displays result of encryption test (Pass or Fail)
AlarmNet Registration:
Displays Account Registration status (Registered or Not Registered)
Test Communication
- Performs network diagnostics and sends test alarms to AlarmNet 360. The following
tests are available depending on the type of communications module installed:
Test Ethernet
This test is available if WiFi communication path is enabled. The network diagnostic process tests the
integrity of the links between the Lyric Controller and the various connection points of AlarmNet Control that
are known as “Redirectors”. If a physical link is detected and is ready, the following diagnostics are
performed.
Testing Gateway…
Traces the connection to the Gateway and displays the following:
Testing Gateway
Successful!
A successful trace to Gateway
Testing Gateway Failed!
Failed to reach Gateway
Testing Redirector *
Sequentially traces the connection to Redirector 1, 2 and 3 at AlarmNet
Control. The following will be displayed:
Redirector * Service OK
Service at AlarmNet Control on Redirector 1, 2 or 3 is functioning.
Redirector * Failed
Error occurred on Redirector 1, 2 or 3.
SUMMARY
Redirector 1 Service OK
Redirector 2 Service OK
Redirector 3 Service OK
A summary of the tests is displayed after Redirector 3 is tested. The
example shows that the tests of all three connection points, or
Redirectors, were successful. If an error occurred at any point, the
summary will display “Failed” next to the faulty Redirector
If no physical link is detected, the test is aborted and one of the following is displayed:
No Physical Link
No physical link is detected.
Link Not Ready
There is a link but it is not ready (address not resolved).
* = Number of the director being tested is displayed
Send Any
If both WiFi and Cellular communication paths are enabled and the Lyric Controller is registered, a Test alarm
is sent over WiFi path. If that is not successful, it sends the alarm over Cellular path.
Send Cellular Message
If Cellular communication path is enabled and the Lyric Controller is registered, a Test alarm to AlarmNet 360
over the Cellular path.
Send Ethernet Message
If WiFi communication path is enabled and the Lyric Controller is registered, a test alarm to AlarmNet 360
over the WiFi path
The following messages are displayed in response to the Send Any, Send Cellular Message and Send Ethernet
Message selections:
Sending Message
Test Message is being sent
Waiting For ACK
ACK Received
The device is registered
Test Message Failed Not Registered
The device is not registered
Setup Communication
– Reset factory defaults. Select the following option:
Factory Defaults The communication device is reset to factory default values.
Communication ID Numbers
The following information is displayed, as applicable to communications path
that has been programmed:
Message
Function
MAC:
Displays Panel MAC address
MAC CRC:
Displays Panel MAC CRC number
WiFi Module
Displays physical address of the WiFi module
WiFi Ver
Displays WiFi Module software version
- 27 -