Lyric Controller Programming Guide
General Programming Information
Lyric™ Lock
This system supports Lyric Lock, an advanced feature designed to keep it functioning optimally. Lyric Lock
capabilities include: the ability to interact with Honeywell and your company’s network for the setup and
programming of system features, support for remote software updates and the ability (when enabled) to
enhance the end user’s security by preventing unauthorized takeover of the system by another monitoring
company. The feature can only be programmed via AlarmNet 360
TM
.
In the event that the end user wishes to authorize another company to take over the system, the end user may
request that Honeywell remotely disable Lyric Lock. Honeywell will require documentation that the end user
has attempted to contact your company three times and that your company has failed to respond, or failed to
agree to the end user’s request.
When power cycling the control, remove AC power first and wait approximately 1 minute before
disconnecting battery. If the system is Armed or in Alarm, the Tools icon will not be functional.
The system must first be disarmed.
Programming options are stored in non-removable, electrically erasable, nonvolatile EEROM memory. The
system can be programmed at any time, even at the installer's premises prior to the actual installation. Simply
apply power temporarily to the Control and then program the unit as desired.
Entering Installer Programming Mode
You may find it convenient to adjust the volume setting before entering the Programming Mode.
This will allow you to clearly hear feedback announcements or system beeps.
1. Power-up the control and allow it to “boot-up”. “System Standby” is displayed on the touchscreen. When
the “boot-up” is complete (approximately 1-2 minutes) “Ready to Arm” is displayed.
2. Select the “Security” icon.
3. Select “Tools” icon.
4. Enter the Installer Code (4 + 1 + 1 + 2) on the displayed keypad.
5. The Installer Tools menu screen appears. Select the “Program” button. “System Programming…” is displayed
in an orange band at the top of the screen. Additionally, the “Panic” button is lit and the “Home” button
alternately flashes red and green.
NOTE: Step 6 is only required if the Controller has not already been associated with an AlarmNet 360
TM
account. If the Controller has been enrolled proceed to step 7.
6. If programming the Lyric locally, program the following fields by selecting the field and entering the
required information on the keyboard. The User Name and Customer Account Number are required in order
for the Lyric Controller to communicate with AlarmNet 360
TM
.
Enter the associated Dealer Identification Number assigned to the
Dealer/Installer.
AlarmNet 360 Password Enter the Dealer’s AlarmNet 360 Password
Alarm Reporting Number Enter the AlarmNet 360 Account Number (City/CS/Sub ID information)
Supervision Time Enter the Supervision Time (None, 24-Hour or 30 Day)
7. Select “Save” when complete.
8. Select one of the following options to advance to that Programming screen:
Installer Code
Date Time
Zones
Keys
System Type
Communicator
Comm. Diagnostics
Reporter
Use the down “˅” arrow to scroll to the second page of options.
Default Config.
Reset Master Code
Z-Wave
Language
9. The system advances to the Programming screen of the selected option.
- 6 -