EasyManua.ls Logo

Honeywell MagneW 3000 Plus - Wetted Materials and Electrical Specs; Wetted Materials and Connections; Electrical Connection and Cable Specs

Honeywell MagneW 3000 Plus
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22 MagneW 3000
PLUS
Specification and Application Guide 1/98
Table 6—Specifications for MagneW 3000
PLUS
, continued
Design (continued)
Wetted Materials
Lining:
2.5 to 600 mm (0.1 to 23.6 in.) diameters—PFA
25 to 200 mm (1 to 7.9 in.) diameters—polyurethane rubber
250 to 600 mm (9.8 to 23.6 in.) diameters—chloroprene rubber
Electrode:
SUS316L, Hastelloy C, Titanium, Zirconium, Tantalum, Tungsten-Carbide,
Platinum/Iridium
Ground ring:
SUS316, Hastelloy C, Titanium, Zirconium, Tantalum, Platinum
Union joint for diameters 2.5 to 15 mm (0.1 to 0.6 in.):
SUS316
Hose for diameters 2.5 to 15 mm (0.1 to 0.6 in.):
SUS316
IDF clamp:
SUS316
Tri-clamp:
SUS316
Gasket:
PTFE gaskets are supplied with ground rings of Hastelloy C, Titanium, Zirconium,
Tantalum, and Platinum. For ground rings made of SUS316, gaskets are supplied by customer;
non-rubber, such as PTFE or joint sheet, is recommended.
O-ring:
Viton rubber (with union joints)
Electrical Conduit 1/2 inch NPT, G1/2, CM20, Pg13.5 internal threads, optional plastic and brass waterproof glands
(G1/2 only)
Nuts and Bolts For wafer construction models only
S20C carbon steel, SUS304 stainless steel
Electrical Connection
Integral:
M4-12P screw terminals
Remote:
Converter—M4-19P screw terminals
Detector—M4-5P screw terminals
Cables
Signal cable:
2-core individually double-shielded cable
Coil excitation current cable:
2-core chloroprene cabtyre cable
Cable Length 300 meters (984 feet) maximum
Grounding Category 3
100 ohms maximum ground resistance
Dimensions See Figures 12 through 20, as applicable.
Weight
Converter:
3.7 kg (8.2 lbs)
Detector:
Refer to Table 8, 9, or 10, as applicable.

Table of Contents