SETTING UP THE MAXPRO NVR
MAXPRO NVR Hybrid Connections
60 MAXPRO NVR 5.0 Installation and Configuration Guide
3
Connecting Control Outputs
Each NVR Hybrid has Control Outputs. These outputs can be used to trigger devices such as
Sirens, Phone Dialers, Lights, and any other relay activated device. There is no power
supplied to the ports. Use an external power supply if necessary.
Figure 3-13 Control Outputs
Use 12V, below 300mA. For controlling lights or other devices, use another external relay.
Maximum voltage is 24V AC @ 1 amp
Output uses a Form C Relay
Note: Please refer to the specific Hybrid unit data sheet for more information on number
of control outputs supported on a specific unit.
Connecting Sensors
Each NVR Hybrid has Sensor inputs. These inputs can be used with devices such as infrared
devices, motion device, glass breakage alarms, door and window trips, and so on. The
Sensors can be set to Normally Open or Normally Closed inside the software.
There are Common Grounds (-) and sensor inputs (+). There is no power supplied to the
ports so an external power supply must be used if power is necessary.