CONFIGURING MAXPRO NVR
Configuring the Cameras
MAXPRO NVR 5.0 Installation and Configuration Guide 161
Note: Analog channels must have Number field value of 1 to 32, please add and
configure all the analog channels required before adding other devices.
• Camera Name - Displays the camera name. You can type a new camera name
limited to a maximum of 50 alphanumeric characters.
• IP Address - This is -.- by default for analog cameras. You can provide any valid IP if
required.
• Camera Type - Displays the type of camera. Select the Analog Capture Card option
to add analog cameras.
•User Name: Displays the default user name, “Admin” for the camera. You can type a
new user name for the camera as applicable. Change this only if the user has been
changed on the camera.
• Password: Displays the password, if any, for the camera. You can type a new
password for the camera as applicable. Change this only if the password has been
changed on the camera.
• Device Stream No: Displays the channel ID. You cannot modify this field.
• Unique System No: Display the unique camera ID. You can modify and assign a
new number as applicable.
• Stream Count: Displays the number of streams associated with the camera. Analog
cameras does not support additional streams. By default it displays 1.
Tip: Based on the Analog Capture Card model, system will prompt a message to add all
supported channels by default. Click Yes to add all supported channels or No to add only 1
channel.
4. For the required camera, click on the left corner to open the camera properties pane
see Figure 6-12.
Figure 6-36 Camera properties pane