184 N4680 2D Decoded Scan Engine User Guide
This response indicates that Codabar Coding Enable (CBRENA) has a range of val-
ues from 0 to 1 (off and on).
Example: What is the default value for Codabar Coding Enable?
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example: What is the device’s current setting for Codabar Coding Enable?
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set
to 1, or on.
Example: What are the device’s settings for all Codabar selections?
This response indicates that the device’s Codabar Coding Enable (CBRENA) is set
to 1, or on
The Start/Stop Character (SSX) is set to 0, or Don’t Transmit
The Check Character (CK2) is set to 0, or Not Required
Concatenation (CCT) is set to 1, or Enabled
The Minimum Message Length (MIN) is set to 2 characters
The Maximum Message Length (MAX) is set to 60 characters
Default setting (DFT) has no value.
Enter: cbrena*.
Response: CBRENA0-1[ACK]
Enter: cbrena^.
Response: CBRENA1[ACK]
Enter: cbrena?.
Response: CBRENA1[ACK]
Enter: cbrena?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].