Honeywell Prestige 2.0 THX9421 - THX9321 Thermostat Wiring Diagrams

Honeywell Prestige 2.0 THX9421
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
THX9321 PRESTIGE
®
2.0 AND THX9421 PRESTIGE
®
IAQ WITH EIM
68-0311—07 144
THX9321 Thermostat Wiring Diagrams
Typical wiring of a 3-heat / 2-cool heat pump system with
one transformer.
Fig. 327. Prestige THX9321 and heat pump system with
one transformer.
Typical wiring of a 2-heat / 2-cool conventional system
with one transformer.
Fig. 328. Prestige THX9321 and 2-heat / 2-cool
conventional system with one transformer.
Typical wiring of a 3-heat / 2-cool heat pump system with
two transformers.
Fig. 329. Prestige THX9321 and heat pump system with
two transformers.
Typical wiring for geothermal radiant heat, geothermal
forced-air and backup heat with one transformer. See
“Geothermal Radiant Heat” on page 100.
Fig. 330. Prestige THX9321 and geothermal radiant
heat, geothermal forced-air and backup heat with one
transformer.
1 U1 and U2 terminals are dry contacts.
2 L/A terminal sends continuous output when thermostat is set to EM HEAT mode except when set up for Economizer or
TOD. See “Economizer Module Wiring Diagrams” beginning on page 154.
3 U1 or U2 terminals must be used for geothermal radiant heat (ISU 2010). Thermostat allows 2 stages of radiant heat—
geothermal (stage 1) and boiler (stage 2).
4 “U” terminals are normally open dry contacts when set up for geothermal radiant heat. You must install a field jumper if
radiant heat is powered by system transformer. Do NOT install a field jumper if radiant heat has its own transformer.
5 Remove jumper if using separate transformers.
6 Connect the THP9045 Wiresaver Module to the K terminal in heating/cooling applications that do not have a common
wire at the thermostat. The K terminal cannot be used in heat-only applications. See THP9045 installation instructions
for more information.
NOTE: For setup and operation, see “Geothermal Radiant Heat” beginning on page 100.
CHANGEOVER VALVE
BACKUP HEAT
COMPRESSOR STAGE 1
COMPRESSOR STAGE 2
FAN RELAY
COMPRESSOR MONITOR
OR ZONE PANEL
120
VAC
O/B
AUX/E
Y
Y2
G
L/A
K
C
Rc
R
U1
U1
U2
U2
24
VAC
Transformer
Thermostat
C
R
1
2
6
M32948A
HEAT STAGE 1
HEAT STAGE 2
COMPRESSOR STAGE 1
COMPRESSOR STAGE 2
FAN RELAY
120
VAC
W
W2
Y
Y2
G
A
K
C
Rc
R
U1
U1
U2
U2
24
VAC
Transformer
Thermostat
C
R
1
5
6
M32949A
31
CHANGEOVER VALVE
COMPRESSOR STAGE 1
COMPRESSOR STAGE 2
FAN RELAY
COMPRESSOR MONITOR
OR ZONE PANEL
120
VAC
O/B
AUX/E
Y
Y2
G
L/A
K
C
Rc
R
U1
U1
U2
U2
24
VAC
Air Handler
Transformer
120
VAC
24
VAC
Backup Heat
Transformer
C
R
R
C
Thermostat
BACKUP HEAT
1
2
6
M32950A
CHANGEOVER VALVE
BACKUP HEAT
COMPRESSOR STAGE 1
COMPRESSOR STAGE 2
FAN RELAY
COMPRESSOR MONITOR
OR ZONE PANEL
120
VAC
O/B
AUX/E
Y
Y2
G
L/A
K
C
Rc
R
U1
U1
U2
U2
24
VAC
Transformer
Thermostat
C
R
GEOTHERMAL
RADIANT
HEAT
STAGE 1
3
2
4
6
M32951A