19 Honeywell
17.
Troubleshooting
Problem Probable
Cause
Suggested Action
Excessive
vibration Build-up of foreign material on impellers
Misalignment
Clean by flushing, or replace worn
parts
Level
meter in piping
Worn
bearings
Replace
bearings
Worn timing
gears
Replace timing
gears
Impellers contacting
body
Rotate manually to
verify
impellers spin freely
High differential
pressure
Heavyweight or too much oil
Dirt
deposits on impellers
Check
oil
level and condition
Remove dirt by flushing
Impellers out of time Retime impellers
Impellers contacting
body
Rotate manually to
verify
impellers spin freely
Low
registration Upstream or bypass
leak
Check all valves for
leakage
Non-registration Broken or binding index
odometer
Obstruction in
meter
Replace
odometer
Remove meter, remove obstructions, flush
meter