Copyright © 2022 Honeywell International Inc. All rights reserved.
How to install “Sunshade/deluge” by the standard installation method:
• Prepare the ordered "Sunshade/deluge" and
two self-contained combination bolts M8*25.
• Referring to the right figure, align the two fixed
holes on the "sunshade/deluge" with the two
strip holes on RAEGuard Lite, respectively.
• First insert one M8*25 combination screw into
the fixed hole ①, and fix it clockwise; then,
insert another combination screw into the fixed
hole ②, and fix it clockwise, as shown in the
figure on the right.
5) Electrical
The RAEGuard Lite transmitter can be connected to three types of sensors depending on
the operating principle of the connected sensor.
5.1) Wiring
Note: All electrical connections must comply with local regulations and standards.
RAEGuard Lite transmitter only supports source current output. The connection method is
as follows:
Note: Make sure that the shielding and grounding of the detector are grounded at a single