2
ATTENTION: MERCURY RECYCLING NOTICE
This product does not contain mercury. However,
this product may replace a product that contains
mercury. Mercury and products containing
mercury should not be discarded in household
trash.
For more information on how and where to
properly recycle a thermostat containing
mercury in the United States, please refer to the
Thermostat Recycling Corporation at
www.thermostat-recycle.org.
For mercury thermostat recycling in Canada,
please refer to Switch the Stat at
www.switchthestat.ca
NO MERCURY
Hg
SUPPLIED PARTS
One (1) thermostat
Two (2) 6-32 mounting screws
Two (2) solderless connectors
Installation
TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.
All cables and connections must comply with local electrical codes.
This thermostat has tinned copper wires for line and load connections.
Special CO/ALR solderless connectors must be used if these wires will be
connected to aluminium conductors.
Install the thermostat onto an electrical box.
Install the thermostat about 5 ft. (1.5 m) high, on an inside wall facing the
heater.
Avoid locations where there are air drafts (such as the top of a staircase or
an air outlet), dead air spots (such as behind a door), or direct sunlight.
Do not install the thermostat on a wall that conceals chimney or stove pipes.
The thermostat wires are not polarized; either wire can be connected to the
load or to the power supply.

Other manuals for Honeywell RLV4300

Related product manuals