5. FittheSunshade/Delugeprotection.
TheSunshade/DelugeprotectionshouldbeclampedaroundthebaseoftheStandardWeatherProtection
with the longer overhang extending beyond the Standard Weather Protection. Ensure the clamp does not
cover the gas venting slot of the Standard Weather Protection.
6. Fitapprovedcableglandstothejunctionboxcableentriesasrequiredtomaintainthecerticationand
IP rating.
7. Fit approved blanking plugs to the unused junction box cable entries as required to maintain the
certicationandIPrating.
8. Fittheexternaleldwiringthroughthecableglandsandsecure.
9. TerminatethegasdetectorandeldwiringinaccordancewithChapter4(ElectricalInstallation).
10. Replace the junction box lid.
3.2.2 Installation with a ow housing (sampling system)
6mm o/d
Outlet
Inlet
Sampling systems should be designed to comply with the Searchpoint Optima Plus operating conditions,
for example, sample temperature, cleanliness, water content, dust content etc.
Inaddition,considerthefollowingpoints:-
1. Flow rate should be between 0.7 litres per minute and 2 litres per minute.
2. Aowfailureindicatorshouldbeincludedinthesystem.
3. If possible, use negative pressure to avoid the risk of pressurisation affecting the gas reading.
4. The choice of sampling lines should be appropriate to the application.