Maintenance
2106M0525 Iss 2 Nov 05 26
Changing the Outer Filter
This procedure applies to all types of Sensepoint gas detector. Refer to the following diagram.
1 Remove the sensor cap (or accessory).
Unscrew the cap/accessory in a counter-clockwise direction.
2 Remove the outer filter.
Discard the old filter.
3 Fit the new outer filter.
4 Refit the sensor cap (or accessory).
Screw the cap/accessory firmly in a clockwise direction.
Sensor Body
1
4
Sensor Cap
New FilterOuter
3
Counter-
clockwise
Clockwise
Outer Filter
2