Specifications
2106M0525 Iss 2 Nov 05 30
General
Detectable Gases
* Maximum certified temperature
Use
Fixed point gas detector for the protection of personnel and plant from flammable,
toxic or oxygen gas hazards.
Gas Type/Gas Ranges
Warm-up
(min)
Operating Temperature*
Minimum Maximum.
Flammable
0-100% LEL
Methane
<10 -40
o
C (-40
o
F) +50
o
C (122
o
F)
Toxic
Ammonia
0-50 ppm
<3
-20
o
C (-4
o
F) +40
o
C (104
o
F)
0-1,000 ppm
Carbon monoxide
0-200 ppm
-20
o
C (-4
o
F) +50
o
C (122
o
F)
0-500 ppm
Hydrogen
0-1,000 ppm
-5
o
C (23
o
F) +40
o
C (104
o
F)
0-10,000 ppm
Hydrogen sulfide
0-50 ppm
-25
o
C (-13
o
F) +50
o
C (122
o
F)0-20 ppm
0-100 ppm
Chlorine
0-5 ppm
<5 -20
o
C (-4
o
F) +50
o
C (122
o
F)
0-15 ppm
Nitrogen dioxide 0-10 ppm <60 -15
o
C (5
o
F) +40
o
C (104
o
F)
Sulfur dioxide
0-15 ppm
<3 -15
o
C (5
o
F) +40
o
C (104
o
F)
0-50 ppm
Oxygen 0-25% Vol <5 -15
o
C (5
o
F) +40
o
C (104
o
F)
Specifications