Specifications
2106M0525 Iss 2 Nov 05 31
Electrical
Physical
Certification
Also see page 33.
Applicable Standards
Environmental
Flammable Toxic/Oxygen Enclosure
3-wire mV bridge
2.9-3.5 Vdc, 0.7 W (max.),
constant current operation at
200 mA
2-wire loop powered
4-20 mA (plus screen),
16-30 Vdc, 0.9 W
Earth continuity plate
BK4 4-wire Terminal block
4-wire, 0.5 to 2.5 mm
2
(20 -14
AWG). Cable entries: 1 x M20,
1 x ½ in. NPT, 1 x ¾ in. NPT
Flammable Sensor Toxic/Oxygen Sensor Enclosure
Material
Polyphenylene Sulfide
(PPS)
Polyphenylene Sulfide
(PPS)
Fire retardant Glass Filled
Polyester (GFP)
Weight
190 g 185 g
205 g oxygen
600 g
Flammable Toxic/Oxygen Enclosure
Ex II 2 G D EEx d IIC
T6 T85°C
T
amb
= -55°C to +55°C
BAS98ATEX2156X
SIRA03ATEX1116X
- Performance
Ex II 2 G D EEx d ia IIC
T4 T135°C
T
amb
= -55°C to +65°C
BAS90ATEX2157X
Ex II 2 G D EEx e II
T6 T85°C
T
amb
= -40°C to +50°C
SIRA04ATEX3018
Flammable Toxic EMC
Standard EN50270 EN445544 (H
2
S only) EN50270
IP rating
IP65, IP66 with Weather housing in accordance with
EN60529:1992
Operating temperature Dependent upon gas type and certification
Operating humidity range
Continuous: 20-90% RH (non-condensing)
Intermittent: 10-99% RH (non-condensing)
Operating pressure 90-110 kPa
Storage conditions Instrument -40°C to +50°C (-40°F to +122°F).