Page 140 SMV800 Modbus User's Guide Revision 1.0
DP, SP, PT Calibration Date
in DDMMYY format.
YY : Year with offset as 1900.
Eg. 0x020376 corresponds to
March 2, 2018.
When read, this will always
give Jan 01 2011 as date.
To read Calibration date
configured for DP, SP and PT
refer respective registers.
Model Key of transmitter
representing the
Differential and Static
Pressure measurement
ranges.
Model
Selection
Guide Part 1
Model Selection Guide
(MSG) Part 1
Model
Selection
Guide Part 2
Model Selection Guide
(MSG) Part 2
Model
Selection
Guide Part 3
Model Selection Guide
(MSG) Part 3
Model
Selection
Guide Part 4
Model Selection Guide
(MSG) Part 4
Comm Module
Temp Up
Count
The total number of minutes
that the Communications
Module/board Electronics
Temperature (ET) has
exceeded the upper stress
limit (ET Upper Limit)
Comm Module
Temp Down
Count
The total number of minutes
that the Communications
Modlue/board Electronics
Temperature (ET) has been
below the lower stress limit
(ET Lower Limit)
User Defined
Variables
Monitoring
User defined variables limit
check configuration for each
variable.
Bit - 0 Enable Monitoring
of User Variable 1
Bit - 1 Enable Monitoring
of User Variable 2
Bit - 2 Enable Monitoring
of User Variable 3
Bit - 3 Enable Monitoring
of User Variable 4
Bit - 4 Enable Monitoring
of User Variable 5
Bit - 5 Enable Monitoring
of User Variable 6
Bit - 6 Enable Monitoring
of User Variable 7
Bit - 7 Enable Monitoring
of User Variable 8