Mode Control or Sensor
Parameter
Value
ALT Hold DADC
VS Hold DADC
FLCH
(IAS/MACH)
DADC
ALT DADC and
Preselect ALT SEL
Control
ARM (ASEL)
ALT Hold
Engage Range
ALT Hold
Engage Error
Pitch Limit
Pitch Rate Limit
VERT Speed Engage
VERT Speed Hold
Engage Error
Pitch Limit
Pitch Rate Limit
Mach Engage Range
Mach
Hold Error
Pitch Limit
Pitch Rate Limit
IAS Engage Range
IAS Hold
Engage Error
Pitch Limit
Pitch Rate Limit
VS Required for
Automatic ASEL ARM
O to 60,000 ft
~40 ft
20 deg up, 15 deg
down
Preset 0.1 g maximum
O to +6000 ft/min
-8000 ft/min
*1OO ft/min
20 deg up, 15 deg down
0.1 g maximum
0.4 to 0.88 Mach
~0.01 Mach
20 deg
up, 15 deg down
0.2 g maximum
80 to 340
KN CAS
&5 KN
20 deg up, 15
deg down
0.2 g maximum
60 ft/min for
3 seconds in the
direction of the ALT
preselect value
System Performance/Operating Limits
Table 205 (cent)
22-14-00
Page 298,40
Aug 15/91