13
Mounting the device
Warning: For satisfactory RF reader performance, you should install the
Voyager device as far as possible from electrical conducting and metal
surfaces. If you install the device on a metal surface, the reading
performance will be affected. For a good performance, install the reader at
least 5 cm away from the metal surface.
Device connectors
All the connections are on the back of the reader inside the round area.
Figure 1 Connectors layout
Connector Function Specification
J1 POE & Ethernet interface RJ45 Female Connector
P4 Output interface 5Pin,--3.5MM pitch, Header connector
P5 TAMPER Switch interface 2Pin,--2.5MM Pitch, Header connector
P6 RS-485 communication
interface
3Pin,--2.5MM Pitch, Header connector