EasyManua.ls Logo

Honeywell TH4210U2002 - System Testing and Specifications; Installer System Test; Specifications

Honeywell TH4210U2002
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10
Specifications
Temperature Ranges
Heat: 40 °F to 90 °F (4.5 °C to 32.0 °C)
Cool: 50 °F to 99 °F (10.0 °C to 37.0 °C)
Operating Ambient Temperature
37 °F to 102 °F (2.8 °C to 38.9 °C)
Shipping Temperature
20 °F to 120 °F (28.9 °C to 48.9 °C)
Operating Relative Humidity
5% to 90% (non-condensing)
Physical Dimensions in inches (mm) (H x W x D)
41/16” H x 41/16” W x 15/32” D
103.5 mm H x 103.5 mm W x 29 mm D
Installer system test
To perform a System Test:
1 Press and hold CENTER and buttons for
approximately 3 seconds to enter advanced
menu.
2 Use to go to TEST. Press Select to enter
System Test.
3 Use to change between Heat, Cool, Fan,
Em. Heat (TH4210U only), or Ver (thermostat
version information). Press Select.
4 Press to turn heat, cool, or fan on. Press to
turn them off.
5 Use the Home button to exit the System Test.
System test System status
Heat
0
Heat Off
1
Heat On
2
Heat On (TH4210U only)
Cool
0
Cool Off
1
Cool On
Fan
0
Fan Off
1
Fan On
Em. Heat
(TH4210U only)
0
Em. Heat Off
1
Em. Heat On
Electrical Ratings
Terminal Voltage (50/60Hz) Running Current
W Heating 2030 Vac 0.021.0 A
(Powerpile) 750 mV DC 100 mA DC
W2 (Aux) Heating (TH4210U only) 2030 Vac 0.021.0 A
E Emergency Heat (TH4210U only) 2030 Vac 0.020.5 A
Y Compressor Stage 1 2030 Vac 0.021.0 A
G Fan 2030 Vac 0.020.5 A
O/B Changeover 2030 Vac 0.020.5 A
L/A Input 2030 Vac 0.020.5 A

Related product manuals