TH8320U AND TH8321U TOUCH SCREEN PROGRAMMABLE THERMOSTATS
69-1706 14
Table 5. Regional Settings Menu.
Select
Installer
Setup
Number
Factory Setting Other Choices
CommentsOption Description Options Description
Changeover 0300 0 Manual changeover 1 1—auto
changeover
Deadband 0310 3 Heating and cooling
setpoints can be set
no closer than 3
°
F
(1.5
°
C)
2 thru 9 Heating and
cooling setpoints
can be set no
c l o s e r t h a n c h o s e n
v a l u e :
2—2
°
F (1
°
C )
3—3
°
F (2
°
C )
4—4
°
F (2.5
°
C )
5—5
°
F (3
°
C )
6—6
°
F (3.5
°
C )
7—7
°
F (4
°
C )
8—8
°
F (4.5
°
C )
9—9
°
F (5
°
C)
Shown only if
automatic
changeover is
selected.
Temperature
Indication
Scale
0320 0 Temperature is
displayed in
°
F.
1 Temperature is
displayed in
°
C.
Daylight
Savings
0330 1 Daylight savings
enabled (United
States).
0 0—daylight savings
is disabled.
Set to 0 in areas that
do not follow
daylight savings.