9. Controller operating parameters
Overview
If required, the 16 basic settings (parameters) can be
adjusted.
Factory settings have a grey background.
Parameters marked with an * are described in more
detail below.
Par. Setting Meaning
1
1
2
3
4
5
6
Language setting
German
English
Danish
Swedish
Norwegian
Finnish
2
0
1
2
Preset time programs *
Week program 1 "At home all day"
Week program 2 "Lunch break at home"
Week program 3 "Part-time work"
3
0
1
Backlight *
Deactivated
Activated
4
0
1
Summer/winter time changeover
No automatic changeover
Automatic changeover
5
0
30
...
90
Duration of the window function *
Window function not active
Valve opens at the latest after 30 minutes
...
Valve opens at the latest after 90 minutes
6
0.2
...
2.0
Sensitivity of the window function during
dropping room temperature *
0.2 (sensitive)
...
2.0 (less sensitive)
Factory setting: 0.4
7
0.1
...
2.0
Sensitivity of the window function during
rising room temperature *
0.1 (sensitive)
...
2.0 (less sensitive)
Factory setting: 0.2
8
0
1
Setting the valve stroke *
Standard valve stroke
Full-stroke mode
9
0
1
Temperature representation in the display
*
Set/programmed temperature (setpoint
temperature)
Measured room temperature
Par. Setting Meaning
10
16
17
...
30
Upper temperature limit
The room temperature cannot be set higher
than the specified upper temperature limit
(Max Limit).
Factory setting: 30 °C
11
5
6
...
15
Lower temperature limit
The room temperature cannot be set lower
than the specified lower temperature limit
(Min Limit).
Factory setting: 5 °C
12
0
1
2
Optimization function *
No optimization
Optimum start
Optimum start/stop
13
3
...
-3
Temperature offset *
To adjust the temperatures measured by
the radiator controller and in the room
Factory setting: 0 °C
14
0
1
2
Battery type
Alkaline
Lithium
NiMH (accumulator chargeable)
15
0
1
Display valve position *
No display of the valve position
Momentary display of the valve position
16
0
1
2
3
4
5
6
7
Valve exercise day *
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
Off
17
0
1
2
Window open function *
Off (no window function)
Auto (corresponding to Parameters 5-7)
Cabled (with floating window contact)
18
0
1
Temperature unit
°Celsius
°Fahrenheit
19
0
1
2
3
Restore to factory setting
No reset
Reset only the basic settings
Reset only the time program
Reset all