711 Air Filter 2
Reminder
Off
Run Time:
10, 20, 30, 45, 60, 90, 120, 150
days
Calendar:
30, 45, 60, 75 days
3, 4, 5, 6, 9, 12, 15 months
Off Both
712 EAC Cell
Reminder
Off
Calendar Months:
6, 7, 8, 9, 10, 11, 12 months
Off Both Electronic Air Cleaner Cell Cleaning Reminder
712 EAC Pre-Filter
Reminder
Off
Calendar Months:
3, 4, 5, 6 months
Off Both Electronic Air Cleaner Pre-Filter Cleaning
Reminder
712 EAC Post Filter
Reminder
Off
Calendar Months:
6, 7, 8, 9, 10, 11, 12 months
Off Both Electronic Air Cleaner Post-Filter Replacement
Reminder
800 Humidifier Type
None
Steam
Bypass / Fan Pwrd
None Both
803 Humidifier Wiring
U1
Thermostat defaults
to the unused
universal terminal
U1.
Both U1 are dry contacts that require power. See
“Wiring IAQ Equipment or a Heat/Cool Stage to
the Universal Terminals” beginning on page 86.
805 Window
Protection
Off
On
Off Both Requires a wired outdoor sensor or connection
to the Internet.
Off: The thermostat controls the humidity level
to the user's desired humidity setting. Frost or
condensation may appear on windows.
On: The thermostat prevents frost or
condensation on windows by not allowing the
humidifier to run above a certain level. To
prevent frost or condensation, the thermostat
may turn off the humidifier before the humidity
setting is reached. See “Window Protection”
beginning on page 58.
Table 2. Installer Setup (ISU) Table. (Continued)
ISU
Number
Installer Setup
Name Settings Default
Residential,
Commercial
or Both Notes