Honeywell VisionPRO TH8000 Series - Wiring and Terminal Connections

Honeywell VisionPRO TH8000 Series
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VisionPRO™THBOOO
Series
Rower
options
::'
HEAT
PUMP
For
24VAC
primary power, connect common
side
of
transformer
to
"C"
terminal.
Wiring
Remove factory-installed jumper
only
for
two-transformer systems.
Insert supplied batteries
for
primary
or
backup power.
Push excess wire back into the wall opening. Plug
wall opening with
non~flammable
insulation.
HEAT
PUMP
Terminal
Designations
Shaded areas below apply ooIy
to
TH83201TH8321.
Conventional
Terminal
Letters:
R Heating power. Connect
to
secondary
side
of
heating system transformer.
Rc
Cooling power. Connect
to
secondary
side
of
cooling system transformer.
C Common wire from secondary side
of
cooling transformer (if 2 transformers).
W 1
st
stage heat relay.
W2
2nd stage heat relay.
Y 1
st
stage compressor contactor.
Y2
2nd stage compressor contactor.
G Fan relay.
51 Optional
outdoor
or
remote sensor.
52
Optional
outdoor
or
remote sensor.
Heat
Pump
Terminal
Letters:
R Heating power. Connect
to
secondary
side
of
heating system transformer.
Rc Cooling power. Connect
to
secondary
side
of
cooling system transformer.
C Common wire from secondary side
of
cooling system transformer.
Y 1
st
stage compressor contactor.
Y2
2nd stage compressor contactor.
Aux
Auxiliary heat relay.
G
Fan
relay.
E Emergency heat relay.
L Heat pump reset (powered continuously
when'System is set
to
Em Heat; system
monitor when set
to
Heat, Cool
or
Off).
0/8
Changeover valve
for
heat pumps.
51 Optional outdoor
or
remote sensor.
52
Optional outdoor
or
remote sensor.
3