VisionPRO™THBOOO
Series
Rower
options
::'
HEAT
PUMP
For
24VAC
primary power, connect common
side
of
transformer
to
"C"
terminal.
Wiring
Remove factory-installed jumper
only
for
two-transformer systems.
Insert supplied batteries
for
primary
or
backup power.
Push excess wire back into the wall opening. Plug
wall opening with
non~flammable
insulation.
HEAT
PUMP
Terminal
Designations
Shaded areas below apply ooIy
to
TH83201TH8321.
Conventional
Terminal
Letters:
R Heating power. Connect
to
secondary
side
of
heating system transformer.
Rc
Cooling power. Connect
to
secondary
side
of
cooling system transformer.
C Common wire from secondary side
of
cooling transformer (if 2 transformers).
W 1
st
stage heat relay.
W2
2nd stage heat relay.
Y 1
st
stage compressor contactor.
Y2
2nd stage compressor contactor.
G Fan relay.
51 Optional
outdoor
or
remote sensor.
52
Optional
outdoor
or
remote sensor.
Heat
Pump
Terminal
Letters:
R Heating power. Connect
to
secondary
side
of
heating system transformer.
Rc Cooling power. Connect
to
secondary
side
of
cooling system transformer.
C Common wire from secondary side
of
cooling system transformer.
Y 1
st
stage compressor contactor.
Y2
2nd stage compressor contactor.
Aux
Auxiliary heat relay.
G
Fan
relay.
E Emergency heat relay.
L Heat pump reset (powered continuously
when'System is set
to
Em Heat; system
monitor when set
to
Heat, Cool
or
Off).
0/8
Changeover valve
for
heat pumps.
51 Optional outdoor
or
remote sensor.
52
Optional outdoor
or
remote sensor.
3