Honeywell VISTA-15P - Arming and Disarming Procedures; Phone Access Features

Honeywell VISTA-15P
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Compatible Devices
Device VISTA-20P VISTA-15P Notes
Addressable Keypads 8 8 6150 Fixed-Word Keypad, 6160 Alpha Keypad, 6150V
Fixed-Word Display Voice Keypad, 6160V Alpha
Display Voice Keypad, 6150RF Keypad/Transceiver
Touch Screen (AUI)
Devices
4 2 Touch Screen (AUI) devices are in addition to the 8
addressable keypads. E.g., Symphony, 6270
4219, 4229 Zone
Expander Modules
Up to 5 for
up to 40
exp. zones
Up to 2 for
up to 16
exp. zones
Zone numbers are predefined according to the device
addresses used. See Expander Module Addresses table
in Wiring section and set addresses accordingly.
5800 Series Wireless Up to 40 RF
zones
Up to 26 RF
zones
Uses 5881/5883 Series Receivers/Transceivers.
Output relays and/or
Powerline Carrier
Devices (X-10 type)
Up to 16 Up to 8 Use any combination of 4204, 4229 and or Powerline
Carrier Devices.
Map output devices via *79 Menu mode.
On-Board Triggers 2 2 Can be used to reset 4-wire smoke detectors.
Output functions Up to 48 Up to 24 Program output functions via *80 Menu mode.
4286 Phone Module Partition 1
only
yes Provides access to the system via on premises or off-
premises phones for arming, disarming, etc., plus
control of relay outputs and Powerline Carrier devices.
Audio Alarm
Verification
Using AAV
module
Using AAV
module
Use ADEMCO UVS or Eagle Model 1250 in
conjunction with an output trigger to permit voice
dialog between an operator at the central station and
a person at the premises. Alternatively, the AVS
system can be used to provide AAV via phone line or
AlarmNet IP/GSM (using a GSMV module).
Alarm output 12VDC, 2
AMP output
12VDC, 2
AMP output
Can drive the compatible sounders; steady output for
burglary/panic, or temporal pulse (3 pulses – pause –
3 pulses – pause – 3 pulses. . .) for fire. Uses current
limiting circuitry for protection.
Auxiliary Power Output See note. See note 12VDC, 600 mA maximum; uses circuit protection.
Backup Battery See note. See note. Rechargeable (sealed lead-acid type) 12VDC, 4AH
minimum.
Long Range Radio
(Communication Device)
See note. See note. Primary telephone number messages can be reported
via ECP connection to various communication devices
(check compatibility/availability of specific models)
AC Power Supply See note. See note. Plug-in 120VAC transformer, 1321 (1321CN in
Canada) or, if using Powerline Carrier devices,
1361X10 Transformer Module
NOTE: All devices and accessories used in a Canadian installation must be Listed for use in Canada.
Important Installation Highlights (Installer Please Read)
This system uses addressable keypads and Zone Expander Modules (see Table of Addresses in
Section 2. Mounting and Wiring – Wiring the Keypads and Other Addressable Devices).
Keypads must be set for addresses 16-23 (first keypad is address 16, which is different from
previous controls) and programmed in data fields *190-*196.
Zone Expander Modules must be set for specific addresses (07-11), based on the zone numbers used.
4204 Relay Modules must be set for specific addresses (12-15).
This control will not power-up unless AC power is connected (will not power-up on battery alone).
However, once the system is powered up, it will operate on battery power in the event of AC loss.
Relays have two programming menu modes: Use *79 Menu mode to map module addresses and
device (output) numbers. Use *80 Menu mode to define the output functions.
This system supports programmable function keys. Use *57 Menu mode to define the function
keys.
Installation and Setup Guide
1-2

Table of Contents