8 - 30
Addenda Timeout
You can set a time during which the scanner looks for a coupon code. If a coupon code is not found within this time period,
the data can be either transmitted or discarded, based on the setting you are using for UPC-A/EAN-13 with Extended
Coupon Code or UPC-A Number System 4 Addenda Required. Set the length (in milliseconds) for this timeout by scanning
the bar code below, then setting the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart,
then scanning Save. Default = 100.
Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
UPC-E0
<Default All UPC-E0 Settings>
UPC-E0 On/Off
Most U.P.C. bar codes lead with the 0 number system. To read these codes, use the UPC-E0 On selection. If you need to
read codes that lead with the 1 number system, use EAN/JAN-13 (page 8-33). Default = On.
UPC-E0 Expand
UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off.
Require Coupon Code, 2 Digit
Addenda, or 5 Digit Addenda
Addenda Timeout
* UPC-E0 On
UPC-E0 Off
On
* Off