hopeSun Series
60KTL, 60KTL-M,
70KTL, 70KTL-M,
75KTL, 80KTL-M
String Type PV Inverter
Quick Installation Guide
1. The contents of this manual are subject to irregular updates
due to product upgrades or other reasons. Unless otherwise
agreed, this manual is only used as guidance. All statements,
information and recommendations in the document do not
constitute any express or implied warranty.
2. In any case, guidance in this manual cannot replace safety
warnings and instructions on user manuals and product
fuselage.
3. All operations of the equipment must be carried out by
professionals. Operators should be fully familiar with the
composition, working principles and standards of the whole
PV system.
4. Before installing the equipment, check whether the delivery is
complete and whether the body has obvious external damage
according to the "packing list". If there are any missing items
or any damage, please contact the distributor.
5. The following two situations occur and are not covered by the
warranty.
Remove the tamper-evident label;
Equipment damage caused by failure to store, handle,
install, and use the equipment in accordance with the
requirements of this manual and the user manual.
1. Product Introduction
Scope of Supply
Inverter Hanging plate* M8 screw sets
M8 expansion bolt
MC4 PV- jack
+ pin
4# Allen wrench
Waterproof lock
Documents
MC4 PV+ pin
+ jack
*The hanging plate is fixed on the back of inverter.
The documents including:
Quick Installation Guide (this manual)
List of Accessories
Inspection Report
Certification
For the model and number of the accessories, please
refer to the List of Accessories.
This figure is only for reference; please refer to the
actual product.
Inverter Front
(1) Upper door
(2) Indicator light
(3) Lower door
Port Description
2. Installation Requirements
Installation Environment
Please install the inverter in a well ventilated
environment, avoid direct sunlight, rain and snow.
√Well ventilated
×Direct sunlight
×Rain and snow
≤60℃
≥-40℃
Ambient Temperature Relative humidity
5%~95%
(The inverter can reach the best working condition
when the temperature is lower than 40℃)
Inverter and hanging plate size
Installation Space
The installation space of single inverter is as following:
≥
500
mm
≥300mm
≥
500
mm
≥200mm
≥
1000
mm
When installing multiple string inverters in a same
surface, the side by side installation is recommended.
When installing multiple string inverters in two lines,
the triangle installation is recommended.
Please install it vertically or tilt it backward at most 15°
to facilitate the heat dissipation of the inverter. Do not
install the inverter at an angle (forward, backward, or
sideways), horizontally, or upside down.
3. Inverter Installation
Installation Steps
1. Unscrew the 4 fixing screws and keep them in a safe
place, and then take out the hanging plate.
2. According to the installation environment, choose a
suitable installation method to install the hanging plate.
Wall/Bracket Mounting
Wall/
Bracket
Expansion
bolt/screws
(M8)
Wall/Bracket punching hole
Screw Rod Mounting
Hoop Rod Mounting
Rod
Hoops
(Provided by
customers)
3. Hang the inverter on the hanging plate.
4. Reinstall the 4 fixing screws removed in the first
step.
4. Electrical Connections
1. When connecting cables, do not operate live and follow the
relevant requirements in the Inverter's User Manual.
2. Before connecting the cable, please complete the following
preparations so as not to cause bodily injury.
(1) Disconnect the inverter DC switch. Ensure that the
inverter is in shutdown state and attach warning signs.
(2) Confirm the positive and negative pole of the input
cable and mark it well. Make sure the connection
between input cable and PV cluster is broken.
(3) It is confirmed that the open circuit voltage of PV
cluster does not exceed the specified limit.
(4) Confirm that the corresponding AC box circuit breaker
is in a state of disconnection.
3. When connecting the input cable, ensure that the positive
and negative poles of the input cable correspond to the
positive and negative poles of the PV terminals of the series
inverter.